Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameM STATION
Address6215 FOREST WAY DR
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/14/2026
Final Score @ Grade
30
General Comments“W” 30 Day Intent to Suspend (ITS) status issued for: records, decking, depth markers, ladder and fitting. Will verify buoy rope on return visit, 50 ft. Note: Skimmer at sunshelf is plugged with 2007 VGB Aquastar dummy cover over plug. Per manufacturer, expired covers should be removed after expiration. More of a hazard is present with cover removed and cover appears to be secure and in good condition. Advised staff to monitor cover and if observed in poor repair should be replaced with updated cover or make sunshelf/pool floor with plug smooth/in good repair with no hazards. This note will be updated for pool. Inspection with Shad McClarin and Chris Ford

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly cyanuric acid. Total alkalinity recorded in wrong section. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit item
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker on pool wall, 3 1/2 FT is dark at top, illegible. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. .2523(c) Depth markers shall include the word "feet" or symbol "ft". *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing step completely at top, missing tread on bottom and loose with rusted screws in sides. .2521(b) Ladders shall have slip-resistant tread. .2521(b) Ladders shall be corrosion-resistant. .2521 Install ladders per manufacturer instructions. *Permit item due to severity Ladders missing rubber caps. Keep in food repair (not permit item at this time)
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Fitting missing by pool equipment room side, possible autofill cover. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *Permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope frayed for buoy and beckets detached. Operator adjusted beckets to proper placement. Rope still has structural integrity, does not warrant immediate suspension, but must be replaced within 30 days or permit will be suspended. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. *permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate propped open on mulch. .2537(b) All gates and doors shall be self-closing, self-latching. Operator removed prop and gate closed. Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping/deck cracked by handicap chair, by sun shelf, tiling offset by 5 FT end/auto fill. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(2) Decks and coping shall be kept in good repair. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water under pumps in equipment room. .2533(d) Pump room floor shall be kept dry and free of standing water.