| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing weekly cyanuric acid. Total alkalinity recorded in wrong section.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*permit item |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth marker on pool wall, 3 1/2 FT is dark at top, illegible.
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
.2523(c) Depth markers shall include the word "feet" or symbol "ft".
*permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing step completely at top, missing tread on bottom and loose with rusted screws in sides.
.2521(b) Ladders shall have slip-resistant tread.
.2521(b) Ladders shall be corrosion-resistant.
.2521 Install ladders per manufacturer instructions.
*Permit item due to severity
Ladders missing rubber caps. Keep in food repair (not permit item at this time) |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Fitting missing by pool equipment room side, possible autofill cover.
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
*Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope frayed for buoy and beckets detached. Operator adjusted beckets to proper placement. Rope still has structural integrity, does not warrant immediate suspension, but must be replaced within 30 days or permit will be suspended.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
*permit item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate propped open on mulch.
.2537(b) All gates and doors shall be self-closing, self-latching. Operator removed prop and gate closed.
Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Coping/deck cracked by handicap chair, by sun shelf, tiling offset by 5 FT end/auto fill.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
.2537(2) Decks and coping shall be kept in good repair.
*permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Water under pumps in equipment room.
.2533(d) Pump room floor shall be kept dry and free of standing water. |