Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed 0.6ppm chlorine. 1.0ppm or more is required.
.2535(4) Maintain chlorine at least 1.0 ppm. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed interior of pool surface to be coming up in multiple places. This is not to the point of the Health Department taking permit action against this pool at this time, but it will likely worsen over time and then may cause the pool to fail inspection and be closed. Steps should be taken to repair the interior surface of the pool before it worsens to that point. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed one ladder to have the lowest tread broken off exposing sharp surfaces and the remaining metal bolts. These surfaces and bolts present a physical injury hazard to swimmers in the pool who may not notice them, or who try to use the ladder anyway. Correct this by repairing or replacing the ladder tread.
Observed the other ladder to be missing the rubber bumper feet. Replace the rubber feet. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring buoy throw rope to have been taken off of the buoy. Rope was reattached and made to be 50 feet long as required at this pool. -CDI |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
. 2537(b) All gates and doors shall be self-closing, self-latching
Observed front gate to self-close, but not to self-latch. This must be corrected.
Observed fence not to current specifications. Gaps under the fence greater than 4 inches. Barrier built prior to 2010. No permit action taken.
.. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck furniture to be too close to the pool edge providing less than 6 feet of space. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
2530(f) Emergency phone shall remain operable. Observed KINGS III call box non-functional. Call box must function to allow call out to local 911 services and allow call-back to the box. Ensure proper number and address are posted at the box and are on-record with local 911 services. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed flow meter to be non-functional. This must be corrected. |