Inspection Date 4/6/2021
Final Score @ Grade
18
General CommentsInspection conducted with Jadarious Benton. Due to COVID-19 precautions, inspection was not signed by the operator. Call button for emergency phone more than 5 feet off the ground. Recommend lowering emergency phone to make it accessible to all bathers. Outer rope on ring buoy fraying. Recommend replacing with a new, U.S. Coast Guard approved ring buoy. Automatic feeder reading 7.6, pH tested at 6.9. Recommend having Caribbean recalibrate the automatic feeder. When calling back the phone number for the emergency phone, the call goes to the fax machine. Contact Kings III to have them adjust the call to go to the emergency phone. Will return next week to check that phone can receive phone calls. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weirs.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash lines extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.