8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some of the weirs not properly installed. .2518(k) Install properly functioning weirs. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not functioning in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some of the pipe labeling worn or missing. .2518(d) Piping and valves shall be labeled with color codes or labels. - Corrected. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash lines extend into the backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |