Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRESLEY OAKS APTS
Address4915 MISTY OAKS DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/2/2019
Final Score @ Grade
26
General CommentsOuter rope on ring buoy frayed. Recommend replacing. Painted portion of contrasting color band fading. .2521(b) Provide 2 inch contrasting color band on leading edge of stair treads. This must be done prior to 2020 pool permit being issued. Emergecy phone located pretty high on the wall. Recommend lowering it to make it more accessible. Intent to suspend issued. 8) 12) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty main drain checks this summer. Ensure that main drains are checked daily, past month was pretty good.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some skimmer baskets full. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. Far skimmer not functioning. .2518(k) The flow-through rate through any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Intent to suspend item. Some weirs missing. .2518(k) Replace missing weirs. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence < 48" in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chipping in places. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Paver at back steps loose. .2537(2) Decks shall be structurally sound. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Vacuum line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No Piping extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.