Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY NORTH
Address100 HERITAGE POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/17/2026
Final Score @ Grade
14
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING AND CANNOT BE OPEN AFTER SUNSET OR BEFORE SUNRISE. MAIN DRAIN COVERS EXPIRE MAY 1ST 2027. OBSERVED SOME DECK TILES TO BE SINKING OR BECOMING OFF-SET. MAINTAIN THE DECK SO THAT OFF-SETS DO NOT EXCEED 1/2 INCH. ENSURE THAT THERE IS A SPARE PUMP BASKET FOR EACH PUMP. INTENT TO SUSPEND FOR THE PUSH BAR ON THE GATE PRESENTING AN OUT OF SPECIFICATION HORIZONTAL SURFACE AND FOR THE CHEMICAL STORAGE PRESENTING A HAZARD DUE TO THE LEAK/SPILL OF AN UNIDENTIFIED LIQUID. DEADLINE IS 10/17/2026. CONTACT C. ELMORE WHEN CORRECTIONS ARE MADE. 704-507-6814. FAILURE TO CORRECT THESE ISSUES MAY RESULT IN THE CLOSURE OF THE POOL UNTIL CORRECTIONS ARE MADE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed gaps in the log sheet where days were missed. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide recordings for cyanuric acid and total alkalinity weekly. These checks must be done everyday the pool is open without exception.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing eyeball fitting. Replace the fitting.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Where barrier consists of both horizontals and vertical members and horizontals are less than 45" apart, the horizontal member shall be located on the inside of the barrier with openings between vertical members no greater than 1.75 inches. Observed the gate near the grills to have a push bar affixed such that it present a horizontal that is less than 45 inches from the other horizontals. Correct this. Ensure that the gate continues to properly self-close and self-latch after the correction. -Intent To Suspend Issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed the wooden shelves and the chemicals on the wooden shelves to be wet with an unknown liquid. This has impacted bags and containers of chemicals on the shelves and in the room. Observed some chemical bags stored on the floor. Clean this area up and store items properly. Use caution when cleaning this area up as the liquid is unidentified and an any hazards associated with it or any reactions it may have with the other chemicals are unknown. Intent To Suspend Issued.