Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY NORTH
Address100 HERITAGE POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/17/2025
Final Score @ Grade
24
General CommentsInspection conducted with Marquis Daws and CPO Dirk Mitchell Dirk Mitchell is the new CPO for the pool. Updated our records. Ring buoy outer rope heavily worn. .2530(f) Provide US Coast Guard approved ring buoy with 45 foot throw rope. - Will follow up in two weeks to ensure it has been corrected. Plexiglas missing on back gate around push bar. Recommend re-installing Plexiglas or other means of restricting access to the push bar. Ensure no gaps > 1/2 inches within 18 inches of the push bar. Gate also has Magna-Latch. Intent to suspend issued 5) 7) 8) 9) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No New Cortland log sheet does not have a place for cyanuric acid or main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 4 weirs missing. .2518(k) Provide functional weirs. - Intent to suspend item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Some depth markers on pool deck loose or chipped on the numbering. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Maintain legible and in good condition. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap does not want to stay closed. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chlorine tank directly in front of fan for chemical storage room blocking most air flow. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Bag of sodium bicarbonate on the pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper in one of the stalls in the men’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.