Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY NORTH
Address100 HERITAGE POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/2/2025
Final Score @ Grade
18
General CommentsInspection conducted with maintenance staff Malik Carter. Outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard Approved ring buoy. Observed new motor on filtration pump. Electrical permit E4701305 passed inspection on 9-17-2024. Observed one depth marker on pool deck chipping. Maintain in good condition. Intent to suspend issued 5) 9) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Missing weekend checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 4 weirs missing. .2518(k) Provide functional weirs.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Some depth markers on pool wall broken and separated from pool wall or is missing. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Maintain legible and in good condition. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chlorine tank directly in front of fan for chemical storage room blocking most air flow. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemicals stored in pump room. Water hose and pressure washer stored in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored by pump and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Bag of sodium bicarbonate on the pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.