NameCORTLAND UNIVERSITY NORTH
Address100 HERITAGE POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/31/2023
Final Score @ Grade
36
General CommentsInspection conducted with CPO Tomas Rivera. Observed no, or very low flow in skimmers, filter pressure ~32 PSI, and leaves in the pump basket. Ensure pool equipment is regularly checked, cleaned, and maintained per manufactuer’s instructions. Intent to suspend issued 5) 7) 8) 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Missing weekend checks and some main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 4 weirs missing. .2518(k) Provide functional weirs. No or very low flow in the skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 40 feet long, tangled and knotted. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope at least 1/4 inch in diameter. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate by pump room drags on the sidewalk. .2528(a) Access gates shall swing away from the pool and be self-latching and self-closing. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor and some shelves in the chemical storage room are wet. .2533(d) Pump room floor shall be kept dry and free of standing water.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower has been removed. .2526(h) Shower(s) shall be provided.