| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No cyanuric acid recordings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. Algae growing on underwater lights and ladder. .2537(14) Keep pool surface and pool floor free of debris. - pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 3 of 4 weirs missing. .2518(k) Provide functional weirs. - Pre-permit item.
Water level above the skimmers. Overflow appears to be clogged or turned off. .2518(k) Water level shall be maintained to assure skimmers are operable. - Pre-permit item. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Outer rope on ring buoy dry rotted. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope at least 1/4 inch in diameter. - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
One depth marker tile loose. .2537(2) Decks shall be kept in good repair. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
General storage items stored next to pool equipment, breakers and valves. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Some dry chemicals stored on the floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed shower on pool deck not operable. .2526(h) Showers shall be provided. |