Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No cyanuric testing reagent. Provide reagent for pool chemical testing. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Back skimmer near sun shelf not pulling. Repair skimmer so operational. Intent to Suspend issued.
One weir missing from skimmer. Replace weir. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate nearest to pump room with 2 1/2" from ground to bottom. Previously had extender on bottom so that maintained 2" or less. Repair to meet 2" or less. Intent to Suspend issued.
Metal magnetic latch provides foothold at side nearest building. Eliminate foothold or increase in height to 45" from ground. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Tumbled pavers. Permit restriction that openings shall not exceed 1/2" on pavers. Noted some areas on coping with paver holes. Some worse. Continue to monitor and fill as needed.
Paver offset near planter - outside of required deck space. Monitor and repair as needed. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Facility provided pool signage does not meet rule requirement. Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Currently missing "swimming". Intent to Suspend issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Operator could not demonstrate that automated chlorinator detects flow. Automated chlorinator/feeder shall detect flow and turn off when no flow. Operator shall be able to demonstrate. Intent to Suspend issued.
Small leak at stick feeder chlorinator. Repair leak. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational. Repair to operational. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Small amount of water under chlorinator due to leak. Keep floor dry.
Muriatic acid stored on top shelf of chemical storage. Acid containers are waterproof and are permitted to be stored on the floor. Store so as not to present a hazard. |