Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY NORTH
Address100 HERITAGE POINTE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/17/2018
Final Score @ Grade
18
General Comments15 - Ring buoy grab rope beginning to degrade. Still intact. Replace within 30 days with USCG approved ring buoy. Intent to Suspend issued for record keeping, depth marker, pool gate, and approved chlorinator.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Pool records missing from end of each month. No alkalinity or acid records. Main drain checks not recorded daily. Intent to Suspend issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Depth marker at 1/2 ft loose. Resecure to pool deck. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Gate closest to pump room with 2 1/2" to 4" under gate due to slope of ground. When repaired, gate shall self-close, self-latch at all times. Intent to Suspend issued. Note: Key fobs disabled on gate entry. Exit button located so that public can access. Eliminate access to push button if utilizing as indicated on previous inspections. Doors from leasing office equipped with audible alarm and self-closing. Door from restroom is self-closing, self-latching.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Facility utilizing Intellichlor Salt cell not sized for swimming pool. Chlorinator must be capable of producting 3 lbs of chlorine per 10,000 gallons. Salt is not approved as primary chlorination. Utilize liquid chlorine or chlorine tab feeder (original approval). Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Liquid acid stored above dry chemicals in pump room. Store as to not present a hazard.