5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No Cyanuric Acid, Total Alkalinity, or weekend checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers 28 feet apart on pool deck close to pump room. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Intent to suspend item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring buoy damaged. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. Removed by operator, other ring buoy still in good condition. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door to restrooms does not latch. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
Cord to Dolphin keeping main door propped open. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
Gate by pump room < 48" high. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
Gate by pump room with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2518(k) One skimmer riser missing, 1" below the top of the pavers. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
One paver to the right of the pool steps missing. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Spare Dolphin stored in pump room, blocking access to some equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Corrected by operator.
Fan in pump room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |