| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.0 .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item.
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
.2518(k) Skimmer top no longer glued and is loose. Surface skimmers shall be installed per manufacturer's instructions. - Intent to suspend item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers 28 feet apart on pool deck close to pump room. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Intent to suspend item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Both ring buoys damaged. One without throw rope, other ring buoy with heavily knotted throw rope. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope. - Immediate suspension item.
Both body hooks are partially hidden by vegetation. Far body hook has vines growing around it, was unable to remove it. .2530(a) Lifesaving equipment should be conveniently located and easily accessible. - Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate by pump room < 48". .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
Gate by pump room door with gaps > 4" through the gate. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item.
Door to restrooms and main gate do not latch. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
Pre-2010 fence with sections < 48" high, and footholds < 45". .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier with no less than 45" between horizontals. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck, looks like surface rust on metal float. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper in one of the men's stalls. .2526(l) Provide toilet paper and dispensers in restrooms. |