Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY CITY
Address1421 BASELINE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/12/2020
Final Score @ Grade
18
General CommentsMain drain covers and equalizer line covers replaced. New 6HPHAxxx covers installed on existing adapter plate. The entire cover, including the backing plate has a lifespan of 5 years and were installed on 5-20-2015. Backing plate will need to be replaced prior to expiration on 5-20-2020 and an updated PDSC form with updated drain cover expiration date will need to be submitted to our office. Green algae growing on pool walls and ladders. Maintain proper water chemistry and pool free of algae. - This is a repeat item. Outer ropes on ring buoys fraying. Recommend replacing with US Coast Guard approved ring buoys. Ensure throw rope is 50 feet long.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Recently started using an Excel spreadsheet for records. No place for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator will start using old form again.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Main drain and equalizer line covers replaced. Updated PDSC form not on file. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Updated form filled out and approved while on site.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected by operator. Most skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door to pool area and both gates not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected by operator. Fence < 48" high where mulch has built up. Ensure fence and gates are at least 48" high. Decorative brick around the building < 45" from the ground, creating footholds at the fence. Maintain fence with no footholds < 45".