Premises Information

Return to Inspections
NameCORTLAND UNIVERSITY CITY
Address1421 BASELINE RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/8/2018
Final Score @ Grade
30
General CommentsGreen algae growing on pool walls and ladders. Maintain proper water chemistry and pool free of algae. - This is a repeat item. Outer ropes on ring buoys fraying. Recommend replacing with US Coast Guard approved ring buoys before next pool season. Provide updated CPO information for CPO. Intent to suspend issued. 5) 8) 17) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance activities. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain cyanuric acid at no more than 100ppm. - Intent to supsend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Leaves and debris on the pool floor. Keep pool surface and pool floor free of debris.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Some skimmer tops are no longer glued and are loose. Surface skimmers shall be installed per manufacturer's instructions. - Intent to supsend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) One of the throw ropes too short. Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence < 48" high where mulch has built up. Ensure fence and gates are at least 48" high. Decorative brick around the building < 45" from the ground, creating footholds at the fence. Maintain fence with no footholds < 45".
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Some furniture too close to pool edge. Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item. .2522(h) Hose bibb at far side of pool broken. Provide hose bibs so that all arears of deck can be reached with a 100 ft hose. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Flow meter stuck. Keep flow meter operational. - Intent to suspend item.