| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine to be at 0.7ppm. 1.0ppm is required for safety. -I.S. Issued. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH to be at or below 6.8. Color was off of the acid scale of the test kit. 7.2-7.8 is required for safety. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed no log book. CPO stated that log book was destroyed. Start and keep a new log book. -I.S. Issued. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed missing skimmer EQ line cover on pool wall. This is a suction hazard. Line cover must be replaced with a proper model of cover. A new PDSC sheet may be required. -I.S. Issued |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed pool wall green with biofilm growth. Clean the pool. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed skimmer baskets to be soiled with debris. Keep skimmer baskets clean. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed one chipped depth marker at the 4.5ft. depth. Repaint the depth marker. The marker numbers must be at least 4 inches tall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring buoy damaged and needing replacement. Observed buoy not to have throw rope. A new ring and rope were obtained and put into place. 36ft. rope as required for this pool. -CDI |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed fence not built to current specifications. Fence built prior to 2010. Fence has entire back section that has been destroyed and had a table pulled up to it to aid in access to the damaged area. This is a hazard as the large area with no barrier allows unrestricted access to the pool. This section of fence must be secured to prevent access by children who could drown. An indivdual accessed the pool area by climbing throw the section of damaged fence during the inspection. C. Elmore moved the table away. The fence also has a gate with damaged lock that prevents it from closing and latching. Secure this gate and repair it. All gates must be fully self-closing and self latching. Correct all gates and secure the damaged area of fence. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed furniture to be within 6 feet of the pool edge. All items must be further back than 6 feet. C. Elmore moved the items. Keep them at least 6 feet from the pool edge, remove them from the pool enclosure if they cannot be kept back. -CDI
Observed deck damage at the stair rail around old fill pipe. Patch this deck damage. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed kings III box non-functional. Box must function and have a working call-back number that is posted with local 911 service along with the proper address. Proper address and call-back number must correct and on file with local 911. Box must function. Call back number and address must be both properly posted on the sign and on file with local 911. Call back number must ring back the call box for voice communication with the box. -I.S. Issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed pump room cluttered and unsafe due to paint cans, old equipment, containers, and other items stored in the pump room. At least 3 feet of clear space must be provided around the pump equipment for staff access and safety. Clear out the pump room area. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Drain Line has no air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Observed no sign directing swimmers to shower. Post a shower reminder sign. |