11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders missing end caps.
.2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fencing by 5' with horizontals from brick and fencing less than 45" in height. Pool built '96.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
No permit action |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Several loungers and planters too close to pool. Operator moved items and corrected. No permit action |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Pool built prior to 2004. Items within 3' of pipes and pumps.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting
Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |