Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Reagents observed to be expired. Replace expired reagents with in date reagents to ensure chemical reading accuracy. No permit action. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
Equalizers observed to have all been plugged. No suction hazard. Provide health department with updated PDSE form reflecting the change within the week. No permit action. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing rubber stop.
.2521 Install ladders per manufacturer instructions. Operator provided piece and will install. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fencing by 5' with horizontals from brick and fencing less than 45" in height. Pool built '96.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
No permit action |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Pool built prior to 2004. Items within 3' of pipes and pumps.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting
Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |