Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND SEVENTY SEVEN
Address6530 FREE THROW LN
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/19/2024
Final Score @ Grade
18
General CommentsConducted inspection with CPO Ryan Peters. Equalizers observed to have all been plugged. No suction hazard. Provide health department with updated PDSE form reflecting the change within the week. Main drain covers expiring 6/19/2024. Replace drain covers with new appropriately rated covers and submit an updated PDSE to health department for approval. Replacements and approvals must be complete before current drain covers expire or current permit will be suspended.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Reagents observed to be expired. Replace expired reagents with in date reagents to ensure chemical reading accuracy. No permit action.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Equalizers observed to have all been plugged. No suction hazard. Provide health department with updated PDSE form reflecting the change within the week. No permit action.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber stop. .2521 Install ladders per manufacturer instructions. Operator provided piece and will install.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing by 5' with horizontals from brick and fencing less than 45" in height. Pool built '96. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). No permit action
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Pool built prior to 2004. Items within 3' of pipes and pumps. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.