Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND SEVENTY SEVEN
Address6530 FREE THROW LN
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/9/2021
Final Score @ Grade
24
General CommentsImmediate Suspension for emergency phone. Contact Marie Daley at 704-507-6806 to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept. "E" Immediate Suspension status No signature due to COVID Inspection with Ryan Peters Report to ryan.peters@cortland.co; Caitlin.tuttle@cortland.com

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer observed with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder slightly loose by 4 1/2 FT depth marker. Keep tight and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing by 5' with horizontals from brick and fencing less than 45" in height. Pool built '96. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck being repaired at time of inspection. Observed small area of decking by 4 1/2 FT depth marker with offset greater than 1/2". .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(2) Decks shall be kept in good repair. *permit item
22 6 Premises: emergency telephone provided No No No Emergency phone not operable at time of inspection. .2530(f) Emergency phone shall remain operable. Immediate Suspension item. Pool must REMAIN CLOSED until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room and on floor. Pool built '94. Items within 3' of pipes and pumps. Pump room unlocked at time of inspection. Water on floor in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2533(d) Pump room floor shall be kept dry and free of standing water.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower off due to cold weather at time of inspection. .2526(h) Shower(s) shall be provided.