| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
7
|
2
|
Thermometers provided, accurate: .2804, .2807, .2808, .2836 |
No |
No
|
No |
15A NCAC 18A .2806 (j) (1) Each refrigerator shall be provided with a numerically scaled indicating thermometer that is accurate to ± 3 degrees Fahrenheit and located to measure the air temperature in the warmest part of the refrigerator. Recording thermometers that are accurate to ± 3 degrees Fahrenheit may be used in lieu of indicating thermometers. Observed thermometer located in rear of kitchen refrigerator.
15A NCAC 18A .2807 (h) Metal stem-type, thin probe, numerically scaled indicating product thermometers, accurate to ± 3 degrees Fahrenheit shall be used to ensure the maintenance of the internal cooking temperatures of all potentially hazardous foods required under this Rule. During time of inspection center could not locate a metal stem type thin probe thermometer. |
|
20
|
0
|
No identified lead poisoning hazards in accordance with NCGS 130A-131.7(7): .2816 |
No |
No
|
No |
15A NCAC 18A .2816 (b) (1) Child care operators, as defined under G.S. 110-86(7), shall test, once every three years, all water outlets used for drinking or food preparation. Samples shall also be collected and tested within 30 calendar days of completion of any renovations or repairs that may impact the facility's drinking water infrastructure, such as repair or replacement of all or part of drinking water service lines or faucets, at impacted outlets. The operator shall provide documentation of testing results for review by the Department during each unannounced routine sanitation inspection. EHS advises center to complete updated round of lead water and asbestos testing. (Website to complete testing is in general comments). Center has received testing kit according to Director. |
|
21
|
0
|
Properly sized, located, accessible, and in good repair; sinks, toilets and potty chairs cleaned and disinfected; proper change of use procedure: .2817, .2818, .2836 |
No |
No
|
No |
15A NCAC 18A .2817 (a. All toilet fixtures shall be kept clean and in good repair. Observed 1 loose toilet seat in PreK restroom. |
|
39
|
2
|
Equipment clean and in good repair; maintained as required: .2826 |
No |
No
|
No |
15A NCAC 18A .2826 (a). In child care centers, all rooms and enclosed areas shall be lighted by natural or artificial light. Lighting shall be capable of illumination to at least 50 foot-candles at work surfaces. Lighting shall be capable of illumination to at least 10 foot-candles of light, at 30 inches above the floor, in all other areas, including storage rooms. Observed light not operating in pantry area. |
|