NameMATTHEWS GLEN
Address720 OAK TERRACE CT
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/23/2026
Final Score @ Grade
20
General CommentsInspection completed with James DuHaime present. Permit suspended for the following items listed below. Once corrected, contact Eli Freese at 704.621.2298 to verify and reopen pool. Ensure pool closed signs are posted while permit suspension is active. 1. Chlorine at 0ppm. 2. The pH at 6.8. Permit conditions - Flow meter must remain operable. Flow required at 41GPM to 120 GPM to meet turnover and flow restriction of the number of returns. Feature pump required at 3110 RPM or less so design flow of pump does not exceed suction pipe flow rate. Check valve must remain in place on drain line in backwash pit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm. Permit suspended.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 6.8. Permit suspended.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed missing main drain safety checks for month of April, 2026.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder missing rubber end cap. Replace.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. Observed one toilet in changing room not operational. Repair.