2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) Certified Food Protection Manager (C)
The Person In Charge (PIC) shall be a certified food protection manger who has shown proficiency of required information through passing a test that is a part of an accredited program. REPEAT.Provided several options of Certified Manager.REPEAT |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
Yes |
Yes
|
No |
4-101.19 Nonfood-Contact Surfaces (C)
Metal shelving racks throughout warewash area, walk-in-cooler, reach-in-cooler at front counter, dry storage and wall mounted shelving racks shall be free of a thick rust accumulation and peeling paint and constructed of a smooth, easily cleanable and non absorbent material. Suggested liners that are made of waterproof material(i.e. plastic, rubber, etc.)REPEAT
4-101.19 Nonfood-Contact Surfaces (C)
Nonfood-contact surfaces of metal panel inside of ice machine has began to rust; that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.Informed Person-in-charge!
4-501.12 Cutting Surfaces (C)
Deeply stained cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they can no longer be effectively cleaned and sanitized or discarded. Person-in-charge cleaned.CDI |
|
49
|
0
|
Non-food contact surfaces clean |
No |
No
|
Yes |
4-602.13 Nonfood Contact Surfaces (C)
Interior surfaces of reach-in-cooler shall be thoroughly cleaned to sight and touch and free of a thick accumulation. Given special attention to corner areas. According to operator. Coca Cola is scheduled to replace. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
Yes |
6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C) REPEAT
The following areas shall be in good repair.
A. Water damaged ceiling tile in the dining area;
B. Peeling, and cracked walls at rear dry storage room and
C. Cracked and missing floor tilessurfaces at rear dry storage room and walk-in-cooler.
D. Base board at ladies toilet room shall be re-secured. And
E. Lower Missing compartment to refridgeration filter at upright meat freezer
F. Sheetrock walls that are pitted and container holes at handwashing sink front counter, warewash/refridgeration area
G.Wall surfaces throughout rear dry storage. And
H. Broken wall partition at front counter adjacent to register.
6-201.11 Floors, Walls and Ceilings - Cleanability (C)
Baseboard,wall surfaces containing a thick accumulation in corner areas of rear storage adjacent to rack shall be cleaned at an increased frequency to prevent potential contamination.
6-501.114
Non functional reach-in-coolers that are being stored next to front counter kitchen area; shall be in-good repair and/or removed from the operation. Informed person-in-charge. |
|
56
|
1
|
Meets ventilation & lighting requirements; designated areas used |
No |
Yes
|
No |
6-303.11 Intensity - Lighting (C)
Although Lighting intensity at walk-in-cooler has increased compared to prior inspection; lighting intensity shall be at least 10 foot candles of shielded lighting. Notified Person-in-charge. Presently ( 5-6)fcREPEAT
The lighting in several food prep stations were measured at a range between (20-35)fc. The lighting intensity must be at least 50 foot candles on surfaces where employees work with food or equipment.REPEAT |