Inspection Date 7/21/2025
Final Score @ Grade
28
General CommentsSuspension issued for water quality. Pool must remain closed with signage posted until suspension is lifted by Health department. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Other permit items (30 Day Intent to Suspend (ITS)) to verify at return visit include records, deck, including skimmer lids, in good repair, no offsets, replace missing weirs, no gaps greater than 2” under fencing, all gates and doors, self closing, self latching. Send verification of lighting to Marie Daley to maintain night swimming. “E” Immediate suspension status

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. *Immediate suspension.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing at time of inspection. Per CPO, book dropped in pool and discarded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) The pool operator must maintain records for at least six months. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir missing and has not been replaced for multiple inspections. Skimmer baskets with debris. .2518(k) Replace missing weirs. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. *Permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose and missing end caps. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate at back left getting caught on mulch. More than 2” under fencing on right back of pool. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture/games within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved and corrected. Broken cement tiles by handicap chair and broken cement skimmer lids with offsets greater than 1/2”.*Permit item Tiling to left of pool starting to become loose, but not currently severe enough for permit action. Monitor and repair if/before it worsens. .2537(2) Decks shall be kept in good repair. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3’ of equipment. Vent fan out in chemical storage. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower spraying from knob/faucet/wall. .2526(h) Shower(s) shall be provided and keep in good repair.