Premises Information

Return to Inspections
NamePOINTE AT PROSPERITY VILLAGE
Address7304 BRICE KNOLL LN
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/7/2024
Final Score @ Grade
32
General CommentsInspection conducted with CPO Kory Little. Facility originally permitted with push to exit button and magnetic latches on door to clubhouse. Have had recurring issues with door alarm being turned off or not functioning. Will have 30 days to revert door back to how it was originally permitted. Door must be self-closing and self-latching with push to exit button. Outlet not working in pump room. Extension cord run from pump room to chemical storage room, which prevents both from being closed and locked per requirements, or prevents automatic chemical feeder from functioning 24/7 per requirements. Will have 30 days to make corrections. All electrical work must be done by a licensed electrician and all required electrical permits shall be obtained with passing electrical inspection from Mecklenburg County Code Enforcement. Both gates catch on the gate post when closing. Maintain gates self-closing and self-latching. Observed sections between coping and deck where caulking is missing and sections between pavers where polymetric sand has eroded. Maintain deck with no gaps or offsets > 1/2 inch. Leaves and other debris in pump room around pool pumps. Recommend cleaning, this restricts air movement around hot motors and is a fire hazard. Intent to suspend issued 5) 7) 16) 24) 25)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some skimmers with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. Missing two weirs. .2518(k) Replace missing weirs. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Top step loose on ladder. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not securely attached to pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to the clubhouse self-closing or self-latching, audible alarm not working. .2528(a) Ground level doors shall be self-closing, and either self-latching or child protected by audible alarm. - Intent to suspend item. Both gates stick. Gate by clubhouse not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Doors to pump room and chemical storage room propped open. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. - Intent to suspend item. General storage items stored in chemical storage room. Difficult to access chemicals. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Light burned out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Two faucets in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair.