47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-202.16 Nonfood-Contact Surfaces (C)-The floor in the walk in is not smooth. Freezing and thawing has buckled the floor making the freezer door not close properly and causing a build-up on ice to build up on the door and making it hard to open and close. Items in the freezer have had to be moved to the back of the unit as well as an additional chest freezer added to keep food frozen. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-201.11 Floors, Walls and Ceilings - Cleanability (C) Floor coverings shall be designed, constructed and installed so they are smooth and easily cleanable. Repair the floor in the walk-in so that it is smooth and easily cleanable. Floor is uneven and lifting in areas where freezing and thawing has occured making it unable to be cleaned properly.
6-501.12 Cleaning, Frequency and Restrictions (C) Clean the vents in the kitchen and over the dish machine where dust is accumulating. |