| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed missing weir during inspection. CPO corrected during inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Ladders shall have slip-resistant tread. Observed ladder missing slip-resistant tread on second rung. Replace missing tread. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed a rope length of 30 ft. CPO corrected rope length to requirement of 24 ft. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Observed less than 5ft of clearance around pool deck. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Observed flow meter rusted and not operable. Flow meter installed on incorrect line. Install operable flow meter on the inlet line to the chlorinator. Intent to suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(e) Provide a spare basket for pump. No spare pump basket on premises. CPO ordered another one during inspection. Intent to suspend item.
.2518(g) Install flow meter on return line per manufacturer instructions. Observed flow meter leaking underneath pipe. Numbers and lettering starting to fade on the flow meter. Recommend replacing if lettering worsens. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed leak in pump room creating standing water. Repair leak. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(m) Keep restrooms and fixtures clean and in good repair. Loose toilet seat found in Women's restroom. Loose handle on sink observed. tighten to keep fixtures in good repair. |
|