Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOLIDAY INN EXPRESS & SUITES
Address6020 UNIVERSITY POINTE BLVD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/15/2018
Final Score @ Grade
46
General CommentsOperator has been without chlorine for the chlorinator for a week, has been shocking the pool to maintain chorine levels. Only use NSF approved chlorinators to maintain proper disinfectant levels. Some pool wall tiles do not appear to be properly grouted to the pool wall. Grout missing. Recommend regrouting some of the pool tiles. Immediate suspension issues. 2) 22) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected for reinspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Immediate suspension item.
3 6 Water quality: pool water pH No No No 2535(1) pH 6.9. Maintain pH between 7.2 and 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Missing records on some weekends, pH < 7.2 with no corrective actions noted. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. .2535 (4) Cyanuric Acid at 100ppm for the last month. Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Both weirs missing. Replace missing weirs. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Ladder loose. Install ladder per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Inlet fitting missing. Fittings and/or face plates shall be replaced when damaged and kept in good repair. Corrected by operator.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(b) Deck chairs too close to pool edge. Provide at least 5 ft of clear walking space around the pool at all times. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No .2530(f) Phone number posted at emergency phone does not match what 911 has. Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Pool out of chlorine tabs, shocking pool to maintain chlorine levels. Control valve on chlorinator line broken. Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Observed operator vacuuming the pool with skimmer basket removed. Skimmer vacuums may be used in pools with two or fewer skimmers provided the skimmer basket remains in place while the vacuum is in operation. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(6) Light not working in the chemical storage room. Provide sufficient lighting in chemical storage room. .2533(d) Leak at the pool pump. Pump room floor shall be kept dry and free of standing water. .2534(2) Chemicals stored in the pump room. Store all pool chemicals in the chemical storage room.