NameMUSEUM TOWER APARTMENTS
Address525 S CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/6/2022
Final Score @ Grade
44
General CommentsNote: Appears new housing for pump installed. Old housing with model number in pump room at time of inspection. Recommend not removing old motor/housing from pump room as new pump has no placard. Motor on pump is a 1.65 THP motor. Immediate Suspension issued for chlorine, pH and ring buoy rope. Once corrected, contact Katie at 704-309-5494 to schedule a return inspection. Pool Closed signs posted during the inspection. Danny Roman present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine at 0.6 ppm. Maintain chlorine at least 1.0 ppm through chlorinator. Immediate Suspension issued.
3 6 Water quality: pool water pH No No No Pool pH at 7.2. Maintain pH at 7.2 to 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks on log books. Provide section for main drain checks.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Severe etching/discoloration of plaster on pool floor. Edges not sharp. May require re-plaster if worsens. Continue to monitor.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One of two weirs missing from skimmer. Replace weir.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Repeat: Ladder handrails loose. Tighten.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope too short at 15 ft. Required at 18 ft. Re-measured pool at time of inspection to ensure correct length. Immediate Suspension issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage to coping/pavers around sun shelves from chairs. Damage does not appear sharp. May require repair in future if worsens. Continue to monitor. Deck drain grates with some rusting. Repair prior to 2023 operating season. Some areas of deck where grout has chipped out including around some depth markers. May require repair in future if worsens.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Flow meter for chlorinator not functional. Repair flow meter.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Repair flow meter.