Premises Information

Return to Inspections
NameMUSEUM TOWER APARTMENTS
Address525 S CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/14/2020
Final Score @ Grade
46
General CommentsImmediate Suspension issued for water clarity, chlorine and pool pH. Once corrected, contact Katie at 704-309-5494 to schedule a return visit to re-open your pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No .2535(2) Main drains must be clearly visible from the pool deck. Main drains and tiling not clearly visible. Immediate Suspension.
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine reading 0 ppm. Immediate Suspension.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH reading at 6.8 during inspection. Immediate Suspension.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed records not consistently kept.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder not tightly fitted (back pool wall).
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 44 inches in length; rope length required to be 18 ft. CDI - CPO cut rope to required length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed portion of gate 47 1/2 inches in height. .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate no able to self close.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed loose tiles on pool deck. Repair/replace as necessary.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed incorrect wording on signage.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. .2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. Observed flow at max of flow meter. Pump curve shows max of pump is at 85 gpm. Flow meter not working properly.