Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMUSEUM TOWER APARTMENTS
Address525 S CHURCH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/11/2017
Final Score @ Grade
32
General Comments15) Observed rope for ring bouy not easily accessbile. Maintain rope easily accessable in the event of an emergency. Intent to suspend issued for record keeping and gate construction. Items must be competed within 30 days, by 11/10/2017. Contact Katie Wilson by email when repairs are completed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 8.0, reduced to 7.6 during inspection. Maintain pH between 7.2 and 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed cyanuric acid over 100 ppm. Observed no daily checks of main drains. Observed total alkalinity and cyanuric acid not records not completed weekly. Maintain records as required. Cyanuriac acid must be below 100 ppm **Intent Issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate on left side of pool deck not self closing. Observed gaps in gate within 18 inches of the push bar greater than 1/2 inch. Observed top of gate less than 48 inches on left side. Observed foot hold present on front of gate that is 36 inches from next horizontal member. Ensure gate repairs are complete per rule .2528. Gate replaced since original permitting. **Intent Issued.
22 6 Premises: emergency telephone provided No No No Observed no sign for indicating address at pool phone, or sign with dialing instructions. Corrected during inspection, sign replaced. Maintain a sign with dialing instructions, phone number of pool phone, address of pool that is readily visible from the pool deck.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Observed no flow meter on chlorine feeder. Ensure chlorinators meet the NSF 50 requirement.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter not working. Maintain flow meter operating in good repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed exhaust for chemical room blocked by chemical container. Corrected during inspection. moved. Maintain exhaust vent free from obstruction.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Observed no shower sign posted. Post a sign instructing attendants to shower prior to entering the pool