Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH measuring 8.2 according to EHS test kit. CDI: CPO lowered pH to 7.5 by end of inspection. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. CPO states that pump was replaced two months prior. PDSC does not match pump that was observed in the field. Replacement pump is Pentair intelliflo SV + SVRS. New PDSC submission and approval required before permitting. PERMIT DENIED. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed two out of four weirs missing. Replace. |