5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Observed all expired chemicals in chemical test kit available in facility. Chemicals reading near inspector test kit. Obtain new test kit with in date chemicals prior to 05/12/2023 or permit action may be taken. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. - Observed 1 out of 4 weirs missing. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope attached to ring buoy be 35’10” but required rope length is 37’6”. - CDI - CPO corrected rope length while inspector present. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(h) Provide approved pump in good repair. - Permit restrictions require pump to be set and locked at 3110 RPM or lower. Observed pump set at 3150 RPM. - CDI - CPO corrected pump to be set at 3110 RPM. |