22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P- Observed 2 metal containers of pepperoni roll ups in the RIC above 41F. EHS asked if the PIC or food employees had the pepperoni roll ups out of refrigeration this morning. PIC stated they were unsure. All other TCS foods in the RIC were 41F or below. -CDI- PIC voluntarily discarded the pepperoni rolls.
Ensure that all TCS foods are maintained at 41F and below.
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-101.19/4-202.16 Non FOOD-CONTACT SURFACES of EQUIPMENT that are exposed to splash, spillage, or other FOOD soiling or that require frequent
cleaning shall be constructed of a CORROSION-RESISTANT, nonabsorbent, and SMOOTH material. NonFOOD-CONTACT SURFACES shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Observed rust present on the lower portion of the prep surface in the dough making area, and on the green wire shelving throughout the facility. Ensure that all rust is removed, replaced or resurfaced on non-food contact surfaces.
-No point escalation due to notable improvement in the facility from PIC re-caulking the back of facility hand sink to the wall.
4-501.11 Maintain equipment in good repair. Observed condenser fan in the WIF with ice buildup present, PIC had a plastic tray underneath the fan to ensure that no ice or dripping contacts food. Observed no contamination present at the time of inspection. Ensure that the WIF is repaired so that it is no longer having an ice buildup |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.110 Keep waste stored in receptacles so waste is inaccessible to insects and rodents. Observed build up of bags and trash in the shared dumpster area. Ensure that waste is stored inside receptacles.
5-501.110 Keep waste stored in receptacles so waste is inaccessible to insects and rodents. Observed right dumpster right side door open. Ensure that dumpster lids and doors remain closed when not in use.
5-501.114 Drains in dumpsters and waste containers shall have drain plugs in place. Observed no drain plug in the right dumpster. Ensure that drain plug is replaced.
PIC stated that all dumpsters are shared with the whole plaza of restaurants and facilities. PIC showed messages with landlord as well as the signs he created to ensure that other facilities are maintaining proper upkeep of the dumpster area. EHS notes the effort made by the PIC. |