2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.4 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. Operator corrected to 3.0 ppm |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from clubhouse not latching or alarmed that goes onto balcony that leads to pool deck.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*permit item
Pool furniture against fence creating horizontal less than 30” inches height.
.2528(b) Horizontals shall not be located less than 45" in height. Operator removed furniture and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Heater line leaking causing floor to be wet under equipment for spa.
.2533(d) Pump room floor shall be kept dry and free of standing water. |