11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed one ladder loose at deep end. Keep tight and in good repair.
.2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One gate by AC unit not closing and not latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
*Permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 5' of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Dry chemicals stored on floor in chemical storage. Chemicals stored in pump room at time of inspection. Some items within 3' of equipment in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |