Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSILVER COLLECTION AT THE PARK
Address12821 LITTLE PENNY DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/27/2026
Final Score @ Grade
12
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING. INTENT TO SUSPEND ISSUED FOR THE BACK GATE GAPS GREATER THAN 1/2 INCHES WITHIN 18 INCHES OF THE PUSH BAR AND ALSO FOR THE 3/4 INCH SINKING OF THE 1 SKIMMER LID AT THE BACK OF THE LEFT SIDE SUN SHELF. DEADLINE IS NOVEMBER 26TH 2026. FAILURE TO CORRECT THE ITEMS BY THAT DATE MAY RESULT IN CLOSURE OF THE POOL. SALT IS NOT APPROVED AS PRIMARY CHLORINATION. MAIN DRAIN AND EQUALIZER LINE COVERS EXPIRE 5/1/2027. THEY MUST BE REPLACED AND THE PDSC PAPERWORK SUBMITTED AND APPROVED BY THE HEALTH DEPARTMENT PRIOR TO THE EXPIRATION DATE. OBSERVED OTHER SKIMMER LIDS TO BE SINKING INTO THE DECK, BUT NOT TO HAVE EXCEEDED THE 1/2 INCH OFFSET. THESE SHOULD BE ADDRESSED BEFORE THEY GET WORSE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 1 weir missing out of 4.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed the back gate plastic shields to be such that they do not cover the full 18 inch radius from the bar. Observed some gaps in the gate/fence greater than 1/2 inch. Correct the shields and gaps such that there are no gaps greater than 1/2 inch within 18 inches of the push bars.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 1 skimmer lid on the deck at the back of the left side sun shelf to have sunk to where it is 3/4 inch off-set. This must be corrected as it present a trip hazard.