3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH at 7.0.
.2535(1) Maintain pH at 7.2 to 7.8. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gaps greater than 1/2” around gate at gate near bike rack.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
Observed maintenance gate not self latching.
.2528(a) Access gates shall swing away from the pool and be self-latching.
Immediate suspension issued |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed fire pit and chairs within 6’ of deck.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Immediate suspension |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed mechanical ventilation not functioning in chemical storage.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |