10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf. Observed hand sink without paper towels near chicken breading station. CDI-paper towels provided. |
|
23
|
1.50
|
Proper date marking & disposition |
No |
No
|
Yes |
3-501.17 (A) or (B) Date mark/label all TCS foods that are ready-to-eat once opened or prepared and are to be held for more than 24 hours. -Pf. Establish a date marking system consistent with 3-501.17 (A) or (B). Additional date marking system options are found in 3-501.17 (D). Observed spring mix date marked with prep date of 1/3 and a discard date of 1/10. If the day the package is opened is day 1 then discard date can be no later than 1/9. Program for producing date marking stickers will need to be adjusted. Verification Required
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . |
|
43
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 (E) In-use utensils, such as ice scoops or utensils for non-TCS food, must be stored in a clean and protected location. Observed ice scoops stored in a container with debris in it. |
|
44
|
0.50
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-903.11(B)(1) Clean equipment and utensils shall be stored in a self-draining position that allows for air drying. Observed sheet pans wet stacked. Air dry before stacking. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-501.19 During manual warewashing, maintain the wash solution at a minimum of 110F or as otherwise allowed by the detergent manufacturer label. -Pf. Observed hot water at 3-comp sink during active manual cleaning of sheet pans hot water was at 80F. Repair faucet if water temperature cannot produce at least 120F. Verification Required |
|
50
|
0.50
|
Hot & cold water available; adequate pressure |
No |
No
|
Yes |
5-103.11(B) Provide sufficient hot water to meet the peak hot water demands.-Pf. Observed 1 broken water heater (of 3 tankless). Hot water at facility 100F at 1:36PM and 106F at 1:55PM. Hot water not being produced in sufficient capacity. Verification Required |
|
54
|
0.50
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.15 Provide dumpster, waste containers that are of sound construction. Observed dumpster leaking sludgy mess onto ground. Replace dumpster with one without holes |