2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
Observed chlorine measuring 0.0 ppm.
Ensure chlorine is measuring at least 1.0 ppm for compliance.
IMMEDIATE SUSPENSION ITEM. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(d) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Documentation shall include an accurate Pool Drain Suction Compliance Form.
Observed main drain covers and equalizer covers installed without approved PDSC form.
Submit updated PDSC form to Meck County Health Department for approval.
IMMEDIATE SUSPENSION ITEM. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed rope length of ring buoy 2 ft less than required rope length of 45 ft.
Replace with 45 ft rope length.
IMMEDIATE SUSPENSION ITEM. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching.
Observed gate located towards the left side of the pool unable to self-close and self-latch, getting caught on the concrete floor.
Repair gate so that it is self-closing and self-latching.
INTENT TO SUSPEND ITEM. |