3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.8 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
**Immediate suspension item. Posted "Pool Closed" signage. Pool must remain closed until corrected and lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing last two days of entries.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Operator recorded entries for day of inspection. Corrected.
No Certified Pool Operator (CPO) information at time of inspection. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator.
*30 Day Intent to Suspend (ITS) item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed debris and frogs in skimmer baskets.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
One weir missing at time of inspection.
.2518(k) Replace missing weirs.
*30 Day Intent to Suspend (ITS) item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook detached from pole at time of inspection.
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Operator replaced hook on pole and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Side door not latching or alarmed at time of inspection. Side gate gets caught on ground, unable to close. Some gates have meshing moved from around the latching mechanism, creating gaps greater than 1/2" within 18" of latching mechanism.
.2537(b) All gates and doors shall be self-closing, self-latching..2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm..2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
***30 Day Intent to Suspend (ITS) item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items stored in pump room within 3' of equipment including some chemicals.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |