1
|
1
|
PIC Present, demonstrates knowledge, & performs duties |
Yes |
No
|
No |
2-103.11 The PIC shall ensure rules in the code for food safety and handling are met. Foodborne illness risk factor violations today. Corrected during inspection. |
|
22
|
0
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16 Maintain TCS foods in cold holding at 41F or less. Half & Half and salad dressings (keep refrigerated on label) were 45-46F. Half and half was 46F and was voluntarily discarded. Salad dressings in packets were 45F and were moved to cooler drawer. |
|
23
|
0
|
Proper date marking & disposition |
Yes |
Yes
|
No |
3-501.18 Discard the food requiring date labels once the time/temperature window has expired, if it is not labeled, or if the label is incorrect. Salads beneath sandwich prep were date marked to discard on Tuesday. Salads voluntarily discarded as corrective action. Salads were made on Monday (bagged lettuce mix) opened Monday and salads were days old. No points deducted today. Salads were at temperature of 41F and were 4 days old. Make sure employees, however, are following Wendy's procedures for salads and discarding according to Wendy's procedures. |
|
24
|
0
|
Time as a Public Health Control; procedures & records |
Yes |
No
|
No |
3-501.19 Time as a Public Health Control (P) (Pf) Facility uses TPHC for hot holding and cold holding. TCS foods on prep area were not labeled with discard time. Labeled during inspection. Ensure employees are following Wendy's procedures for TPHC. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Good Repair and Proper Adjustment - Equipment (C) Walk-in freezer in dry storage area is not in working order. Ambient air checked was 10F. All frozen foods were moved to other walk-in freezer prior to EHS entering establishment. Door handle and latch was broken on freezer. Workorder placed for freezer. |
|
51
|
1
|
Plumbing installed; proper backflow devices |
Yes |
No
|
No |
5-202.13 Backflow Prevention, Air Gap (P) Cut pipe below prep sink at an angle to allow for a two inch air gap between pipe and drain. A verification visit will be made to ensure this has been corrected. Maintenance fixed pipes after inspection was complete. Violation corrected. |
|
54
|
0.50
|
Garbage & refuse properly disposed; facilities maintained |
No |
Yes
|
No |
5-501.115 Maintaining Refuse Areas and Enclosures (C) Detailed cleaning is needed around dumpsters in dumpster area.
5-501.116 Soiled receptacles and waste handling units must be cleaned regularly to avoid soil accumulation and creating an attraction for insects and pests, and in a manner that does not contaminate food, equipment, utensils, linens, or single-service and single-use articles. Dumpsters need to be cleaned. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-101.11 Surface Characteristics - Indoor Areas Repair broken floor tiles in dry storage area. |