Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN CHARLOTTE AIRPORT
Address2400 CASCADE POINTE BV
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/23/2023
Final Score @ Grade
18
General CommentsInspection conducted with operator, Dana. All permit items corrected during inspection. Night swimming approval will expire this year. Contact Hope McIntosh to discuss renewal of night swimming approval. 980-229-7549

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing CYA and TA in daily records. Operator noted they have water tested by Caribbean weekly but have not transferred data for CYA and TA to records. Operator produced some of the weekly reading print out reports. Going forward, either document weekly CYA and TA in written records or keep copies of printed water testing for CYA and TA levels. No permit action.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Furniture within 6’ of pool. Corrected.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Rules sing currently posted has this statement in 1/2” lettering. Operator corrected by posting additional signage with this statement in letters greater than 1”.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed chemicals stored in pump room. Pool built post 2010. Chemical storage room in use for bulk item storage and not accessible for use. Remove bulk items from chemical storage room to make accessible for pool chemical storage. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Hot water in both restrooms greater than 110 f.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Unable to locate hose bib in or near restrooms used for pool.