Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN CHARLOTTE AIRPORT
Address2400 CASCADE POINTE BV
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/13/2023
Final Score @ Grade
22
General CommentsInspection conducted with Dana Hobson. 30 day intent to suspend the permit issued for gate not self closing or self latching, missing spare pump basket, vacuum line cover does not latch, missing/incomplete record keeping. Once items have been corrected, call Hope McIntosh at 980-229-7549 to request a re-visit. If no visit is request, EHS will return at 30 days. If all permit items not in compliance, permit will be suspended. Night swimming remains approved at this time. Note: pool chlorine exceeding 10 ppm. EHS recommends reducing chlorine level prior to re-opening the pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed required reagents expired. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed multiple missing daily records. No TA or CYA readings available since December. Observed records that may not be accurate - unchanging data. *permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris accumulated in skimmers. Cleaned during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Gate at far end/right side of pool not self closing and not fully latching. *permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. Spare basket provided does not fit pump. Provide spare pump basket for Pentair WFE-4 pump. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Vacuum cap does not latch closed. Provide self-closing self-latching cover that requires tool to open on vacuum line. Pool built 2017. *permit items
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items within 3' of piping in pump room. Observed chemicals stored in pump room. Pool built post 2010. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Hot water in both restrooms greater than 110 f.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Unable to locate hose bib in either restroom or outside of restrooms.