Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN CHARLOTTE AIRPORT
Address2400 CASCADE POINTE BV
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/24/2019
Final Score @ Grade
28
General CommentsNote: Pool rules sign located on inside of the barrier does not meet NC Public Swimming Pool Rules. Signage located at pool entry meets code requirements. Intent to Suspend issued for record keeping, pool gate, flow meter and deck repair. Salt is not approved as primary chlorination.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid and alkalinity not recorded weekly. Record weekly. Intent to Suspend issued. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Two sets of ring buoys on pool deck. One ring buoy and rope with damage and fraying rope. Ring buoy removed from deck during inspection. Additional ring buoy with rope with grab rope beginning to degrade. Still usable. Replace within 30 days. Will verify replacement during return visit for Intent to Suspend items. Ring buoy ropes tangled so not accessible. Corrected during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Exit gate <48" measured from ground. Gate shall be at least 48" from ground with no greater than 2" from ground to bottom horizontal. Intent to Suspend issued. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Polymeric sand used on pavers to ensure impervious surface. Sand has not been maintained and is missing between joints, around skimmers, etc. Reseal pavers with polymeric sand to 6 ft. back from pool. Intent to Suspend issued. Pool furniture 5 ft. to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational. Replace flow meter. If not like for like, flow meter shall be capable of handling at least 1.5x design flow of the pump (98 gpm per pump curve for WFE-4 pump) and must be installed per manufacturer specifications. Intent to Suspend issued. .2518(g) Keep flow meter operational.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No No shower sign posted. Post visible upon entry to the swimming pool. .2526(a) Post a shower sign visible upon entrance to the pool.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >110 F. .2526(i) Water in restrooms shall not exceed 110 F.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in pool restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.