Return to Inspections
NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2026
Final Score @ Grade
16
General CommentsInspection conducted with CPO Travis Deese. Requires 5% flow meter for 2026. Facility installed pressure and vacuum gauges to get true flow reading. Permit Restriction: Flow meter must remain operable. Flow shall not exceed 170 gpm due to main drain flow restriction. Before 2026 permit can be issued, will need to provide updated PDSC form for new pressure and vacuum gauges. (11x2.31)+(7x1.13) = 33.32. 170 GPM per pump curve. Outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy with attached 38 foot throw rope. Paint on pool bottom and pool steps chipping in places. Maintain in good condition, if worsens will need to repaint/replaster.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. CPO checked for today and will start marking in the log book.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Overflow grate damaged. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.