NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/18/2024
Final Score @ Grade
22
General CommentsInspection conducted with CPO Dustin Green and maintenance supervisor Travis Deese. Flow meter reading 137 GPM after a backwash. Observed Sta-Rite pump with 3HP motor. Pump label not observed. Kings III has address for main office. Call Kings III to have them change location to this phone to correct address. Verified that 911 has the correct address for this phone. Intent to suspend issued 5)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No total alkalinity or cyanuric acid checks for April. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper holder missing in one of the women’s stalls. Toilet paper rolls in restrooms empty. .2526(l) Provide toilet paper and dispensers in restrooms.