General CommentsInspection conducted with Jeff Tobin. Due to COVID-19 precautions, inspection was not signed by the operator. Observed Sta-Rite pump with 3 HP motor, no label observed on pump. Observed painted contrasting color bands fading. .2521) The leading edge of stair treads shall be marked with a contrasting color band or line at least two inches (5 cm) wide visible from above the stairs. Use of contrasting color tiles installed in the stair tread is acceptable provided the tiles are spaced no more than one inch (2.5 cm) from the edge of the tread or from adjacent tiles. Prior to 2022 pool permit being issued, provide at least 2" contrasting color band along leading edge of the pool steps that extends to pool walls and edge of steps.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Two ladders with missing endcaps. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs too close to the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap missing. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Men's restroom with broken toilet paper holder. .2526(l) Provide toilet paper and dispensers in restrooms. Florescent lights in women's restroom do not fully turn on. .2526(m) Keep restrooms and fixtures clean and in good repair.