|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Ladder missing endcaps. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Door to fitness center not self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Corrected by operator. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper holder in men's restroom. .2526(l) Provide toilet paper and dispensers in restrooms. |