Premises Information

Return to Inspections
NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/21/2021
Final Score @ Grade
10
General CommentsVisit conducted with Jeff Tobin. Due to COVID-19 precautions, inspection was not signed by the operator. Painted contrasting color band starting to fade. Recommend repainting if it gets worse. Observed Sta-Rite pump with 3 HP motor. No label on pump. Have had issues reading handwritten address on emergency phone signage in the past. Recently rewritten, but would recommend replacing with permanent signage. Permit issued No Night Swimming “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Door to fitness center not self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Corrected by operator.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper holder in men's restroom. .2526(l) Provide toilet paper and dispensers in restrooms.