Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/23/2020
Final Score @ Grade
18
General CommentsInspection conducted with Del Plumley. Due to COVID-19 precautions, inspection was not signed by the operator. Observed contrasting color bands have been repainted. Observed Sta-Rite pump with 3 HP motor, no label observed on pump. Permit issued. No Night Swimming Can contact Will Harrison (704-507-6824) to schedule lighting inspection when pool lighting is fixed. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two weirs missing. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Two ladders missing endcaps. .2521 Install ladders per manufacturer instructions.
18 4 Premises: lifeguards present or warning signs posted No No No Signage not posted advising that Children should not use the swimming pool without supervision. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line extends into drain for backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Mens restroom missing toilet paper holder, one stall in women's restroom without toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms.